Recommended Bolt Size ?The suggested bolt diameter for optimal installation

Max Axial Static Load Rating ?The maximum static load that can be applied along the axis

A ?Dimension A of the component

B ?Dimension B of the component

C ?Dimension C of the component

D ?Dimension D of the component

E ?Dimension E of the component

F ?Dimension F of the component

Center Bonded Mounts CBA Series

Center Bonded Mounts isolate vibration, control shock and reduce noise due to structure borne vibrations.

Available in a full range of rated load capacities and able to withstand shock loads of 10 g’s, these mounts effectively protect equipment and improve operator comfort. They are ideal for automotive, marine, railroad and industrial markets.

Center Bonded Mounts provide flexible suspension systems for mobile, transport-mounted or portable equipment. Typical applications include engines, cabs, fuel tanks, pumps, air conditioning units, compressors and industrial machinery.

Downloads

Sort By
Show
Item #
Recommended Bolt Size (in)
Max Axial Static Load Rating (lbs) at Deflection
A (in)
B (in)
C (in)
D (in)
E (in)
F (in)
Actions
5/8
650 at 0.10
2.35
0.657
1.5
2.11
1.5
0.69
3/8
100 at 0.09
1 1/4
0.41
0.95
1.44
1.07
0.55
3/8
200 at 0.09
1 1/4
0.41
0.95
1.44
1.07
0.55
0.5
300 at 0.09
2
0.54
1.38
2
1.45
0.75
0.5
300 at 0.09
2
0.545
1.38
2
1.45
0.75
0.5
400 at 0.10
2
0.54
1.38
2
1.45
0.75
0.5
400 at 0.10
2
0.545
1.38
2
1.45
0.75
5/8
500 at 0.09
2.35
0.657
1.5
2.11
1.5
0.69
5/8
500 at 0.09
2.35
0.655
1.5
2.11
1.5
0.69
3/4
1600 at 0.12
3.3
0.785
1.62
2.5
1.94
0.88
5/8
650 at 0.10
2.35
0.655
1.5
2.11
1.5
0.69
3/4
800 at 0.10
2.8
0.81
1.62
2.38
1.63
0.69
3/4
800 at 0.10
2.8
0.785
1.62
2.38
1.63
0.69
3/4
1050 at 0.10
2.8
0.81
1.62
2.38
1.63
0.69
3/4
1050 at 0.10
2.8
0.785
1.62
2.38
1.63
0.69
3/4
1200 at 0.11
3.3
0.81
1.62
2.5
1.94
0.88
3/4
1200 at 0.11
3.3
0.785
1.62
2.5
1.94
0.88
3/4
1600 at 0.12
3.3
0.81
1.62
2.5
1.94
0.88